Walk-In-Stability Chamber

walk-in-stability chamber

Description

The Walk-in Stability Chamber is engineered to meet ICH, WHO, and USFDA standards, offering reliable performance for stability testing, shelf-life studies, and packaging evaluations. Designed with a durable stainless-steel inner chamber (SS 304/316) and a microprocessor-based PID control system, it ensures accurate regulation of temperature and humidity. With a wide temperature range of 20°C to 60°C and humidity control from 40% RH to 90% RH, it provides consistent environmental conditions for sensitive pharmaceutical and industrial products. The chamber includes CFC-free cooling systems, steam-based humidification, and air circulation technology for uniform conditions. As a trusted Stability Chamber Manufacturer, Cintex offers advanced Walk-in Stability Chambers designed for the pharmaceutical, cosmetic, and food industries to deliver precise, dependable, and compliant performance.

Walk-In-Stability Chamber

  • Designed for testing product shelf-life, packaging, and electronic tests.
  • Specially designed to meet ICH, WHO, and USFDA requirements.
  • Double-walled construction with Inner SS 304 chamber and exterior finished in powder-coated shade in Regular Model.
  • Inner SS 304/SS 316 and exterior SS 304 matt/buff finish in GMP Model.
  • Temperature and humidity controlled by microprocessor-based PID temperature and RH% controller with dual digital indicator and PT-100 sensor for temperature, and capacitance type sensor for RH%.
  • Cooling kit is CFC-free, including hermetically sealed compressor, condenser, and fan motor, safely placed at the back of the chamber.
  • Humidification through steam injection system, providing humidity levels from 40% RH to 95% RH (humidity stability: ±2% RH to ±3% RH). Humidity varies with temperature — lower temperature gives lower humidity, higher temperature gives higher humidity.
  • Air circulation system ensures better stability and even distribution inside the chamber.
  • Boiler tank with water heater having auto cut-off facility and audio alarm for low water level.
  • Reservoir water tank with float valve provided.
  • Overload protection relay and time delay provided for compressor safety.
  • Temperature Range: 20ºC to 60ºC; Temperature Accuracy: ±1ºC.
  • Humidity Range: 40% RH to 90% RH; Humidity Accuracy: ±2% RH to ±3% RH.
  • Suitable racks provided on both sides to install trays.
  • Shelves are SS wire mesh or SS rod type (standard for all units).
  • Two-pane glass window provided on the door for clear observation of tests, with an ancillary heater between the glass to prevent condensation.
  • Illumination provided through fluorescent tubes for clear visibility of tests.

Optional

  • Printer output facility to record PV, SV, actual date/time with variable print time intervals, 5000-line memory, and audio alarm in case of memory full.
  • Temperature scanner (4-channel / 8-channel) with printer output facility to record temperature and RH at various points inside the chamber.
  • PLC-based touch screen control system with printer output facility.
  • Automatic changeover to standby cooling system.
  • GSM mobile alert feature for real-time notifications.
  • 21 CFR Part 11 compliance software for data management.
  • Alarm hooter facility for system alerts.
Cat No. Capacity Inner Size (W × D × Ht.) (Approx.) Trays per Chamber (Nos.)
CU CFT Ltrs
CIC – 121 A 190 5400 54” × 80” × 80” 24
CIC – 121 B 280 8000 80” × 80” × 80” 24
CIC – 121 C 428 12000 100” × 80” × 96” 32
CIC – 121 D 570 16000 80” × 160” × 80” 60