Bio-Safety Cabinet (Type A2 Class II)
Designed with an open front with
i) Inward airflow for the user protection.
ii) Downward HEPA- Filtered laminar sterile airflow for contamination prevention.
iii) HEPA – filtered exhaust air for environmental protection.
iv) 70% Air Recirculate & 30% Air Exhaust through bleed Hepa Filter into room.
ii) Downward HEPA- Filtered laminar sterile airflow for contamination prevention.
iii) HEPA – filtered exhaust air for environmental protection.
iv) 70% Air Recirculate & 30% Air Exhaust through bleed Hepa Filter into room.
Utility
Can be used for work with toxic chemicals employed as an adjunct to microbiological processes since no re-circulation occurs.
Safety
One of the safest BSCs where the total exhaust feature acts as a fail-safe in the event the down flow and / or exhaust HEPA filtration systems ceases to function normally.
Specification
- Working Opening: Safety Height < 200 mm / 400 mm
- Inflow Velocity: Inflow 0.53 m/s, Downflow 0.33 m/s
- Filter: Two HEPA filters, 99.97% efficiency at 0.3 microns
- Front Window: Toughened glass sash with position sensor
- Noise: EN12469 < 58 dB, NSF < 61 dB
- UV / Fluorescent Lamp: 30W UV / 40W x 2 fluorescent
- Illumination: > 1000 Lux
- Gas Tap: 1
- Digital Magnehelic Gauge: Provided
- Display: LCD Display
- Castor Wheel: Universal wheel
- Material: Inner SS 304 working table, outer MS/GI powder coated shade
- Power Consumption: 600 W
- Standard Configuration: Control system, UV light, LED tube for illumination, base stand
- Motor Blower: Dynamically balanced blower/motor assembly with spring suspension
- Dynamic Motor: Yes (inbuilt)
Size and Price
| CAT NO. | WORKING AREA | SIZE OF FILTER | HEPA FILTER | PRE FILTER | ILLUMINATION WITH UNIT | U.V. LIGHT |
|---|---|---|---|---|---|---|
| CIC – 38 | 3’ x 2’ x 2’ | 3’ x 2’ | 1 | 1 | 1 x 40 watts | 1 x 3’ |
| CIC – 38 | 4’ x 2’ x 2’ | 4’ x 2’ | 1 | 1 | 2 x 40 watts | 1 x 3’ |
Bio-Safety Cabinet (Type B2 Class Ii)
Triple Protection
i) Inward airflow for the user protection.
ii) Downward HEPA- Filtered laminar sterile airflow for contamination prevention.
iii) HEPA – filtered exhaust air for environmental protection.
iv) 100% Exhaust.
ii) Downward HEPA- Filtered laminar sterile airflow for contamination prevention.
iii) HEPA – filtered exhaust air for environmental protection.
iv) 100% Exhaust.
Utility
Can be used for work with toxic chemicals employed as an adjunct to microbiological processes since no re-circulation occurs.
Safety
One of the safest BSCs where the total exhaust feature acts as a fail-safe in the event the down flow and / or exhaust HEPA filtration systems ceases to function normally.
Specification
- Working Opening: Safety Height < 200 mm / 400 mm
- Inflow Velocity: Inflow 0.53 m/s, Downflow 0.33 m/s
- Filter: Two HEPA filters, 99.97% efficiency at 0.3 microns
- Front Window: Toughened glass sash with position sensor
- Noise: EN12469 < 58 dB, NSF < 61 dB
- UV / Fluorescent Lamp: 30W UV / 40W x 2 fluorescent
- Illumination: > 1000 Lux
- Gas Tap: 1
- Digital Magnehelic Gauge: Digital type provided
- Display: LCD Display
- Castor Wheel: Universal wheel
- Material: Inner SS 304 working table, outer MS/GI powder coated shade
- Power Consumption: 600 W
- Standard Configuration: Control system, UV light, LED tube for illumination, base stand
- Motor Blower: Dynamically balanced blower/motor assembly with spring suspension
- Dynamic Motor: Yes (inbuilt)
Size and Price
| CAT NO. | WORKING AREA | SIZE OF FILTER | HEPA FILTER | PRE FILTER | ILLUMINATION WITH UNIT | U.V. LIGHT |
|---|---|---|---|---|---|---|
| CIC – 70 | 3’ x 2’ x 2’ | 3’ x 2’ | 1 | 1 | 1 x 40 watts | 1 x 3’ |
| CIC – 70 | 4’ x 2’ x 2’ | 4’ x 2’ | 1 | 1 | 2 x 40 watts | 1 x 3’ |