Description
The Shaker Water Bath / Metabolic Water Bath is a precision-engineered unit designed for tissue culture, metabolism, cell incubation, protein coagulation, and enzyme studies requiring controlled temperature and reciprocal shaking. It features an insulated double-walled chamber with an inner SS 304 tank and a powder-coated GI/MS exterior in the regular model, while the GMP model offers both inner and outer SS 304 with a matt finish for superior durability and hygiene. The shaking speed can be digitally adjusted from 50 to 200 RPM using a digital speed controller, and a 24-hour digital timer with an alarm ensures precise operation. Temperature control is managed by a microprocessor-based PID controller with a dual digital display and a PT-100 sensor for high accuracy. The cooling model includes a hermetically sealed compressor, condenser, and fan motor to achieve temperatures down to 0°C. It also comes with a stainless steel shaking platform suitable for Erlenmeyer flasks or test tubes, along with a gable cover to prevent splashing at higher speeds, making it ideal for demanding laboratory applications.
Shaker / Metabolic Water Bath
- Ideal for tissue, metabolism, cell incubator, protein coagulation, and enzyme studies requiring reciprocal shaking under controlled temperature conditions.
- An insulated bath chamber having inner 304 SS and exterior of GI/MS powder coating finish – in REGULAR MODEL.
- Inner chamber 304 and exterior 304 SS matt finish in GMP MODEL.
- Speed of stroke adjustable from 50 RPM to 200 RPM by digital speed controller.
- Digital timer of 24 hrs with alarm included in panel.
- All models are with microprocessor-based PID temperature controller with dual digital indication & Pt 100 sensor.
- Cooling shaking bath includes hermetically sealed compressor, condenser, fan motor, etc., for temperature down up to 0°C.
- Stainless steel shaking platform having perforation and suitable for Erlenmeyer flasks or test tubes.
- Gable cover to prevent splash at higher speed.
Optional
- Printer output facility required to record PV, SV, actual date/time with variable print time interval, 5000 line memory, and audio alarm facility in case of memory full.
- 21 CFR Part 11 compliance software for data management.
| CAT. NO. | SIZE OF BATH (L × W × HT) | CLAMP CAPACITY | STROKE LENGTH | TEMP. RANGE |
|---|---|---|---|---|
| CIC – 9 A | 20” × 16” × 10” | 12 Nos. × 250 ml or 8 Nos. × 500 ml | 40 MM | 5°C above ambient to 99.9°C |
| CIC – 9 B | 16” × 12” × 10” | 12 Nos. × 100 ml or 6 Nos. × 500 ml | 40 MM | 5°C above ambient to 99.9°C |
| CIC – 9 C | 22” × 18” × 10” | 12 Nos. × 250 ml or 8 Nos. × 500 ml | 40 MM | 0°C to 90°C |
| CIC – 9 D | 18” × 14” × 10” | 12 Nos. × 100 ml or Rack of 40 Test Tubes | 40 MM | 0°C to 90°C |