Bio Safety Cabinet

Bio-Safety Cabinet (Type A2 Class II)

Designed with an open front with i) Inward airflow for the user protection.
ii) Downward HEPA- Filtered laminar sterile airflow for contamination prevention.
iii) HEPA – filtered exhaust air for environmental protection.
iv) 70% Air Recirculate & 30% Air Exhaust through bleed Hepa Filter into room.

Utility

Can be used for work with toxic chemicals employed as an adjunct to microbiological processes since no re-circulation occurs.

Safety

One of the safest BSCs where the total exhaust feature acts as a fail-safe in the event the down flow and / or exhaust HEPA filtration systems ceases to function normally.

Specification

  • Working Opening: Safety Height < 200 mm / 400 mm
  • Inflow Velocity: Inflow 0.53 m/s, Downflow 0.33 m/s
  • Filter: Two HEPA filters, 99.97% efficiency at 0.3 microns
  • Front Window: Toughened glass sash with position sensor
  • Noise: EN12469 < 58 dB, NSF < 61 dB
  • UV / Fluorescent Lamp: 30W UV / 40W x 2 fluorescent
  • Illumination: > 1000 Lux
  • Gas Tap: 1
  • Digital Magnehelic Gauge: Provided
  • Display: LCD Display
  • Castor Wheel: Universal wheel
  • Material: Inner SS 304 working table, outer MS/GI powder coated shade
  • Power Consumption: 600 W
  • Standard Configuration: Control system, UV light, LED tube for illumination, base stand
  • Motor Blower: Dynamically balanced blower/motor assembly with spring suspension
  • Dynamic Motor: Yes (inbuilt)

Size and Price

CAT NO. WORKING AREA SIZE OF FILTER HEPA FILTER PRE FILTER ILLUMINATION WITH UNIT U.V. LIGHT
CIC – 38 3’ x 2’ x 2’ 3’ x 2’ 1 1 1 x 40 watts 1 x 3’
CIC – 38 4’ x 2’ x 2’ 4’ x 2’ 1 1 2 x 40 watts 1 x 3’

Bio-Safety Cabinet (Type B2 Class Ii)

Triple Protection

i) Inward airflow for the user protection.
ii) Downward HEPA- Filtered laminar sterile airflow for contamination prevention. 
iii)  HEPA – filtered exhaust air for environmental protection.
iv) 100% Exhaust.

Utility

Can be used for work with toxic chemicals employed as an adjunct to microbiological  processes since no re-circulation occurs.

Safety

One of the safest BSCs where the total exhaust feature acts as a fail-safe in the event the down flow and / or exhaust HEPA filtration systems ceases to function normally.

Specification

  • Working Opening: Safety Height < 200 mm / 400 mm
  • Inflow Velocity: Inflow 0.53 m/s, Downflow 0.33 m/s
  • Filter: Two HEPA filters, 99.97% efficiency at 0.3 microns
  • Front Window: Toughened glass sash with position sensor
  • Noise: EN12469 < 58 dB, NSF < 61 dB
  • UV / Fluorescent Lamp: 30W UV / 40W x 2 fluorescent
  • Illumination: > 1000 Lux
  • Gas Tap: 1
  • Digital Magnehelic Gauge: Digital type provided
  • Display: LCD Display
  • Castor Wheel: Universal wheel
  • Material: Inner SS 304 working table, outer MS/GI powder coated shade
  • Power Consumption: 600 W
  • Standard Configuration: Control system, UV light, LED tube for illumination, base stand
  • Motor Blower: Dynamically balanced blower/motor assembly with spring suspension
  • Dynamic Motor: Yes (inbuilt)

Size and Price

CAT NO. WORKING AREA SIZE OF FILTER HEPA FILTER PRE FILTER ILLUMINATION WITH UNIT U.V. LIGHT
CIC – 70 3’ x 2’ x 2’ 3’ x 2’ 1 1 1 x 40 watts 1 x 3’
CIC – 70 4’ x 2’ x 2’ 4’ x 2’ 1 1 2 x 40 watts 1 x 3’